Frost protection heating cable 11W/m for inside or around pipes

€15,56 incl. 21% VAT

Keep your application frost-free, now reduced in price!

This heating cable is available with or without an internal thermostat, making this cable extremely suitable for many purposes.

Installation is very straightforward, all you need is aluminium tape or other fixing materials!

Aluminium tape 50m *

Clixon *

Length

Product price: €15,56 incl. 21% VAT
Total options:
Order total:

The 11SRF constant wattage heating cable is an efficient solution for frost protection of pipes and installations. The cable is available with an integrated clixon (thermostat) or as a version without a clixon in combination with an external temperature control. This allows the cable to be used flexibly for various applications.

Version with clixon (thermal switch)

The 11SRF with clixon automatically switches the heating cable on and off based on the ambient temperature. The clixon automatically switches the heating cable on when the ambient temperature drops to +3°C and switches it off again when the temperature rises to +12°C. When the cable is switched on, it delivers its full output. Outside this range, the cable will hardly heat or not heat at all. The clixon is located at the end of the cable.

This version is suitable for standard frost protection of pipes where no separate external control is required.

Important:
The cable with clixon is exclusively suitable for installation around the pipe. When placed inside a pipe, the clixon may not function optimally and an external control may still be required.

Please note: The heating cable must not be crossed. This can cause the cable to overheat and become damaged.

Version without thermal cut-out (constant power)

The 11SRF without thermal cut-out is a constant-wattage heating cable. This means that the cable outputs the same power along its entire length, regardless of the ambient temperature.

Because the version without a clixon continuously emits heat, an external thermostat or control is required.

The version without a thermal cutout can be used in combination with a suitable external controller for internal pipe tracing.

Applications

The 11SRF heating cable is widely used for:

  • Frost protection for water pipes
  • Protection of external pipes and pipework in unheated rooms
  • Applications in crawl spaces, sheds and technical installations
  • Industrial applications where constant heating is desired

Technical specifications

  • constant power heating cable
  • Power: 11 W/m
  • Supply voltage: 230 V
  • Enclosure rating: IPX7
  • Installation: around the pipe or (without thermal cutout) internally applicable
  • Scheme:
    • With klixon: automatic temperature switching (+3°C to +12°C)
    • Without thermal cutout: external control possible

Practical and purposeful

Thanks to the choice between a version with or without a clixon, the 11SRF heating cable can be easily tailored to the application. For quick installation, you choose the variant with a clixon; for more control and specific situations, the version without a clixon offers maximum flexibility.

Please note: For some products in our webshop, a basic knowledge of electrical engineering is required.

Specificaties

Type cable

11SRF

Power

(@10°C): 11W/m

Temperature

(on/off) : Max 65°C

Dimensions

8.3 × 5.7 mm

Outer sheath

thermoplastic

Tension

230V

ATEX

No

Width

8.3mm

Dictation

5.7mm

Insulation

thermoplastic

Internal regulation

Clixon (When this option is chosen)

Safety class

IPX7

Temperature range

Up to 65 degrees Celsius

Downloads